How to maintain the high and low temperature test chamber? The high and low temperature test chamber is mainly used in the high and low temperature test natural environment of aerospace commodities, electronic equipment, etc. Scientific and standardized maintenance of the high and low temperature test chamber can not only greatly increase the service life of the high and low temperature test chamber, but also reasonably prevent technical common failures caused by refusal to perform maintenance.
1、 Clean the cooler in time
Under normal conditions, the cooler shall be cleaned for many times every three or six months. If the air cooled water cooling is selected for the refrigeration compressor, the cooling centrifugal fan shall be repaired quarterly and the cooler shall be decontaminated and dusted to ensure its excellent natural ventilation and heat transfer characteristics; If water-cooled cooling water is selected for the refrigeration compressor, in addition to ensuring the working pressure and temperature of water leakage, it is also necessary to ensure the relative total flow, and clean the scale inside the cooler quarterly to obtain its continuous heat transfer characteristics.
2、 The working temperature should be moderate
The temperature of high and low temperature test chambers is usually relatively high. We propose to place them in a more benign natural environment. Our work experience temperature value is 8 ℃~21 ℃. For laboratories without this standard, appropriate air conditioners or closed cooling towers must be configured.
3、 The management personnel should be technical and professional
Persist in the professional management method of full-time personnel. Enterprises with standards should regularly send full-time personnel to the supplier's processing plant to learn and train, so as to obtain more professional maintenance and repair work experience and ability.
4、 Clean water channel and air humidifier quarterly
Cleaning of water channel and air humidifier; If the water channel is blocked and the air humidifier is easy to burn due to scaling, the air humidifier will be damaged. Therefore, the water channel and air humidifier must be cleaned every quarter.
5、 Clean the air conditioner evaporator quarterly
Clean the air conditioner evaporator quarterly: because the cleaning levels of the weighing samples are different, under the effect of the forced air circulation system, many small particles such as floating dust on the air conditioner evaporator should be cleaned quarterly.
6、 Clean the centrifugal fan of air supply mode blade and condenser quarterly
Cleaning and balancing of centrifugal fan of air supply mode blade and cooler: similar to cleaning of air conditioning evaporator, due to different office environments of environmental test box, there are many small particles such as floating dust on the centrifugal fan of air supply mode blade and cooler, which should be cleaned quarterly.
7、 After the experiment, the work should be sound
Persist in setting the temperature around the working temperature after each experiment, disconnect the switching power supply after 40 minutes of work, and clean the interior of the personal studio.